METROLOGIC INSTRUMENTS, INC.MS7120 Series Fixed Projection Laser ScannerInstallation and User’s GuideMLPN 2408Printed in USADecember 1998

Página 2 - Locations

6Scanner Installation: Powered by Host DeviceThe MS7120 scanner interfaces terminate to a 10-pin modular jack. Connectthe 10-pin modular plug of the

Página 3 - Table of Contents

7Scanner Installation to the PC for the Scanner with Built-inPC Keyboard Wedge Interface To maintain compliance with applicable standards, all circuit

Página 4 - Table of Contents (continued)

8Green and Red LEDs: During normal operation, the greenLED is on. This indicates that the laser is on and the unit isready to scan. On a successful re

Página 5 - Introduction

9Audible Indicators When the MS7120 scanner is in operation, it provides audible feedback.These sounds indicate the status of t

Página 6 - Scanner and Accessories

10Failure Modes Flashing Green and One Razzberry ToneThis indicates the scanner has experienced a laser subsystem failure. Retu

Página 7 - Quick Start

11Visual Indicators There are a red LED and a green LED on the head of the Orbit MS7120.When the sc

Página 8 - Operational Test

12LabelsEach scanner has labels on the bottom of the unit. One label containsinformation such as the model number, date of manufacture, serial number

Página 9

13Depth of Field Specifications (based on 100% UPC bar codes)Optimal Low Density Depth of Field (default)Optimal High Density Depth of Field

Página 10

14Depth of Field Specifications (continued)(based on 100% UPC bar codes)Close Depth of FieldNormal Depth of Field

Página 11 - PC Keyboard Wedge Interface

15Depth of Field Specifications (continued)(based on 100% UPC bar codes) Far Depth of Field

Página 12 - ú

iiLocationsUSA Corporate Headquarters EuropeMetrologic Instruments, Inc. Metrologic Instruments GmbH90 Coles Road Dornierstrasse 2Blackwood, NJ 08012

Página 13 - Three Beeps - on power up

16Depth of Field by Minimum Bar Code Element WidthOptimal Low Density Depth of Field (default)

Página 14 - Failure Modes

17Depth of Field by Minimum Bar Code Element Width(continued)Optimal High Density Depth of Field (default)

Página 15

18Depth of Field by Minimum Bar Code Element Width(continued)Close Depth of Field

Página 16

19Depth of Field by Minimum Bar Code Element Width(continued)Normal Depth of Field

Página 17 - (based on 100% UPC bar codes)

20Depth of Field by Minimum Bar Code Element Width(continued)Far Depth of Field

Página 18

21MaintenanceSmudges and dirt can interfere with the proper scanning of a bar code.Therefore, the output window will need occasional cleaning. 1. Spra

Página 19

22Troubleshooting GuideThe following guide is for reference purposes only. Contact a Metrologicrepresentative at 1-800-ID-METRO or 1-800-436-3876 to p

Página 20

23Troubleshooting Guide (continued)SYMPTOMS POSSIBLE CAUSE(S) SOLUTIONThe unit powers Beeper disabled. No tone Enable beeper. Select toneup, but does

Página 21 - (continued)

24Troubleshooting Guide (continued)SYMPTOMS POSSIBLE CAUSE(S) SOLUTIONScanner beeps at The print quality of the bar Check print mode. The type of prin

Página 22

25Troubleshooting Guide (continued)Keyboard Wedge OnlySYMPTOMS POSSIBLE CAUSE(S) SOLUTIONThe unit scans Configuration is not Make sure the scanner is

Página 23

iiiTable of ContentsIntroduction ... 1Scanner and Accessories ...

Página 24

26Troubleshooting Guide (continued)RS-232 onlySYMPTOMS POSSIBLE CAUSE(S) SOLUTIONPower-up OK Com port at the host is not Check to make sure that the b

Página 25 - Maintenance

27RS-232 Demonstration ProgramIf an RS-232 scanner is not communicating with your IBM compatible PC, key in thefollowing BASIC program to test that

Página 26 - Troubleshooting Guide

28Applications and ProtocolsThe model number on each scanner includes the scanner number andcommunications protocol.Scanner Version Identifier Communi

Página 27

29Appendix ADesign SpecificationsOperationalLight Source: VLD 675 ± 5nm, 0.681 milliwatts (PEAK)Depth of Field: 0 mm to 215 mm (0" to 8.5"

Página 28

30Appendix A (continued)ElectricalInput Voltage: 5.2VDC ± 0.25VPower : 1.1 WOperating Current : 225 mADC Transformers: Class II; 5.2 V @650 mA Laser

Página 29

31Appendix BDefault SettingsMany functions of the scanner can be "programmed" - that is, enabled ordisabled. The scanner is shipped from the

Página 30

Appendix B (continued)32Parameter Default OCIA RS- Light IBM KBW232* Pen 46XXDTS/NIXDORF * TTNCR F TTNCR S TTPoll Light Pen Source TTBeeper Tone Norma

Página 31 - RS-232 Demonstration Program

Appendix B (continued)33Parameter Default OCIA RS- Light IBM KBW232* Pen 46XXTransmit UPC-A Item ID# * TT TT TT TT TTTransmit Codabar TT TT TT TTSta

Página 32 - Applications and Protocols

Appendix B (continued)34Parameter Default OCIA RS- Light IBM KBW232* Pen 46XXCharacter RTS/CTS * TTMessage RTS/CTS TTXON/XOFF Handshaking TTACK/NAK T

Página 33 - Appendix A

Appendix B (continued)35Parameter Default OCIA RS- Light IBM KBW232* Pen 46XXNormal Depth of Field * TT TT TT TT TTExtended Depth of Field TT TT TT TT

Página 34 - Appendix A (continued)

ivTable of Contents (continued)Appendix ADesign Specifications 29, 30Appendix BDefault Settings 31-35Appendix CPin Assignments 36-38Appendix DWarranty

Página 35 - Appendix B

36Appendix CPin AssignmentsPin Assignments for the PowerLink CableThe MS7120 scanner interfaces terminate to a 10-pin modular jack. Connect the 10-pin

Página 36 - Appendix B (continued)

37Appendix C (continued)Pin Assignments for the PowerLink Cable Keyboard WedgeInterface The MS7120 Keyboard Wedge scanner interface terminates to a 10

Página 37

38 Adapter Cable Connectors 5-pin Male 6-pin Female PowerLink Cable Connectors 5-pin Female 6-pin Male Appen

Página 38

39Appendix DWarranty and DisclaimerLimited WarrantyProducts manufactured by Metrologic have a 2-year limited warranty fromdate of manufacture.This war

Página 39

40Appendix D (continued)DisclaimerMetrologic Instruments, Inc. and the author or authors make no claims or warranties with respectto the contents or a

Página 40 - Appendix C

41Appendix ENoticesNoticeThis equipment has been tested and found to comply with limits for a Class A digital device,pursuant to Part 15 of the FCC Ru

Página 41 - Appendix C (continued)

42Appendix E (continued)AnmerkungNach Überprüfung dieses Geräts wurde festgestellt, daß es den Grenzwerten für Digitalgeräte derKlasse A gemäß Teil 15

Página 42

43IndexAAccessories 2AC input/outlet 2, 4, 5, 7Adaptercable 2, 7, 38Approvals 12Assignmentspin 36-38Audible indicators 9Authorized service center 39Au

Página 43 - Appendix D

44Index (continued)Light Pen 1, 2, 4, 6, 28, 36Light source 29List 2MMaintenance 21Manufacturer’s recommendation7Mechanical 29Min bar width 29NNormal

Página 44 - Appendix D (continued)

1IntroductionOrbit™ is an aggressive, omnidirectional laser bar code scanner. Light-weightand rugged, Orbit is small in size, but BIG in performance.

Página 45 - Appendix E

2Scanner and AccessoriesThe following is a list of the parts included in the MS7100 kit.! MS7120 Laser Scanner - Refer to page 28 for available commun

Página 46 - Appendix E (continued)

3Quick Start 1.) Plug in the scanner. When the MS7120 is ready to scan, the green LED will turn on, then the red LED will flash and the scan

Página 47

4Operational TestMetrologic recommends using the external power supply provided with thescanner when operating the MS7120. When using power supplied b