Metrologic IS4815 Guia de Instalação Página 18

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 32
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 17
14
SCAN ENGINE TERMINATIONS
IS4813 Pinout Connections
IS4813 10-Pin ZIF
Figure 9. 10-Pin ZIF
Pin Signal Name Function
1 No Connect No Connect
2 Power 3.3V ± 10%
3 No Connect No Connect
High = Laser OFF
4 Laser Enable*
Low = Laser ON,
only if pin 5 (scan enable) is also Low
High = Engine OFF
5 Scan Enable*
Low = Engine ON
High = Bar
6 Digitized Bar Pattern
Low = Space
7 Start of Scan
Level changes from high to low, or low to high,
when the laser changes direction at the start of
the scan line.
8 Ground Power Ground
9 Ground Power Ground
10 No Connect No Connect
* See Scan Sense Timing on page 16.
Vista de página 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23 ... 31 32

Comentários a estes Manuais

Sem comentários