SCAN SENSE TIMING
Barcode Element Time Calculation
Realization of the full depth of field for all barcodes given in the specification is
based on the ability of the decoding hardware to resolve a varying range of
minimum element times. The minimum element time calculation for a given
barcode size at a given distance is shown in Equation 1(below).
Minimum Element Time = (Element Size / Spot Speed)
Equation 1.
Example:
Barcode Size = 5.2 mil
Spot Speed @ 95 mm from face = 650 inches/second
Minimum Element Time = (0.0052 inches/ (650 inches/second)) = 8.0 µsec