Metrologic MS1890 Focus Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Leitores de códigos de barras Metrologic MS1890 Focus. MetroSelect® Single-Line Configuration Guide Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - Configuration Guide

METROLOGIC INSTRUMENTS, INC.MetroSelect®Single-LineConfiguration Guide00-02544G_cover.qxd 3/13/2006 5:11 PM Page 1

Página 2

4 CODE TYPES AND DECODE RULES CODE 128 ³100113 * Enable Code 128 ³100103 Disable Code 128 ³100314 Enable UCC/EAN-128 ‘]C1’ Code Formatting -For

Página 3 - ABLE OF CONTENTS

April 2007, Version 01 Printed in the USA 00-02544H

Página 4

5CODE TYPES AND DECODE RULES CODE 39 ³100215 Enable PARAF (Italian Pharmaceutical Codes) Support - Code 39 bar codes are converted to PARAF format

Página 5

6 CODE TYPES AND DECODE RULES CODE 39 ³115413 Enable Alternate Code 39 Reference ComparisonCheck – assists with elements that are below the 2 to 1

Página 6

7CODE TYPES AND DECODE RULES 2 OF 5 CODES ³100913 Alternative ITF 1st Bar Reference ³100903 * Normal ITF 1st Bar Reference ³100110 Enable Standar

Página 7 - INTRODUCTION

8 CODE TYPES AND DECODE RULES 2 OF 5 CODES ³100316 Enable Hong Kong 2 of 5 ³100306 * Disable Hong Kong 2 of 5 ³115411 Enable Follett ITF ³115401

Página 8 - NEED TO START OVER?

9CODE TYPES AND DECODE RULES CODABAR ³100114 * Enable Codabar ³100104 Disable Codabar ³100012 Enable Dual Field Codabar ³100002 * Disable Dual F

Página 9

10 CODE TYPES AND DECODE RULES TELEPEN ³100017 Enable Telepen ³100007 * Disable Telepen ³100016 Enable ALPHA Telepen ³100006 * Disable ALPHA Telep

Página 10 - CODE TYPES AND DECODE RULES

11CODE TYPES AND DECODE RULES PLESSEY CODES ³108003 * Standard Plessey Stop Characters ³108013 Accept Bad Plessey Stop Characters ADDITIONAL DE

Página 11

12 CODE TYPES AND DECODE RULES CONFIGURABLE CODE LENGTHS There are seven bar code lock lengths available. Specific code types can be assigned to

Página 12

13CODE TYPES AND DECODE RULES CONFIGURABLE CODE LENGTHS ³903000 ~ Code Length Lock #6 ³903100 ~ Code Type Lock #6 ³903200 ~ Code Length Lock #7

Página 13

Copyright © 2007 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, trans

Página 14

14 SUPPLEMENTS ³101217 Enable Two Digit Supplements ³101207 * Disable Two Digit Supplements ³101212 * Enable Two Digit Redundancy - The scanner w

Página 15

15SUPPLEMENTS ³101417 Enable Bookland (978) Supplement Required ³101407 * Disable Bookland (978) Supplement Required ³101314 Enable 977 (2 Digit)

Página 16

16 SUPPLEMENTS ³101000 * Enable 2 Digit Supplements with 37x, 43x, or UPC # System 5 ³101010 Disable 2 Digit Supplements with 37x, 43x, or UPC # S

Página 17

17SUPPLEMENTS ³101214 Enable Code ID’s with Supplements ³101204 * Disable Code ID’s with Supplements ³118406 * Beep Once on Supplements ³118416 B

Página 18

18 SUPPLEMENTS ³101210 Disable Supplementals when CodeGate Button is Pressed - Available for MS9540 scanners only. Requires standard Code Gate be i

Página 19

19RSS BAR CODE IMPLEMENTATION Metrologic’s MS9520 Voyager® and MS9540 VoyagerCG® laser scanners with software #14810 and higher can be configured t

Página 20 - SUPPLEMENTS

20 RSS BAR CODE IMPLEMENTATION RSS LIMITED BAR CODES ³100414 Enable RSS Limited ³100404 * Disable RSS Limited ³114903 * Transmit RSS Limited CD

Página 21

21ISBT CODE 128 IMPLEMENTATION CONFIGURATION MODE BAR CODES ³138417 Enable ISBT Code 128 ³138407 Disable ISBT Code 128 These bar codes are used

Página 22

22 ISBT CODE 128 IMPLEMENTATION CONCATENATION CONFIGURATION MODE BAR CODES Supported by the MS9500 series only The following bar codes are used t

Página 23

23ISBT CODE 128 IMPLEMENTATION PRE-DEFINED CONCATENATION CONFIGURATION MODE BAR CODES ³4384100Donation Identification Number + Confidential Unit E

Página 24

ii TABLE OF CONTENTS Introduction ... 1 Bar Cod

Página 25 - RSS BAR CODE IMPLEMENTATION

24 ISBT CODE 128 IMPLEMENTATION Supported by the MS9500 series only. The following example demonstrates how to configure the User-Defined ISBT ide

Página 26

25 COMMUNICATIONS ³415524 Enable Light Pen/Wand Communication - Use this option if scanner should be used in place of a light pen. ³415554 * Enabl

Página 27 - ISBT CODE 128 IMPLEMENTATION

26 SCANNER OPERATION CONFIGURATION MODE OPTIONS ³118117 Allow Configuration Mode on Power Up - the scanner can only enter MetroSet mode before a

Página 28

27SCANNER OPERATION REDUNDANT SCANS ³301100 * 0 Redundant Scans - Requires 1 good decode for a good scan. ³301110 1 Redundant Scan - Requires 2 c

Página 29

28 SCANNER OPERATION SAME SYMBOL TIME OUTS The length of time before a bar code can be rescanned after it is removed from the scan field is user-c

Página 30 - =&³=G&a505d0

29SCANNER OPERATION BEEPER OPTIONS ³318575 * Normal Tone ³318565 Optional Tone 1 ³318555 Optional Tone 2 ³318545 Optional Tone 3 ³318535 Optional

Página 31 - COMMUNICATIONS

30 SCANNER OPERATION BEEPER OPTIONS ³118417 Beep on BEL Command - The scanner beeps when it receives a BEL character from the host. If a number

Página 32 - SCANNER OPERATION

31SCANNER OPERATION DATA TRANSMISSION DELAYS Use these codes to select the amount of delay between sending data characters from the scanner to th

Página 33

32 SCANNER OPERATION COMMUNICATION TIME OUT OPTIONS ³118412 Enable Communications Time Out ³118402 * Disable Communications Time Out ³118413 *

Página 34

33SCANNER OPERATION HOST SCANNER COMMANDS ³118015 Enable D/E Disable Command. - The scanner will disable scanning after it receives an ASCII “D” f

Página 35

iiiTABLE OF CONTENTS Miscellaneous Decode Features ... 27 Same Symbol Timeouts ...

Página 36

34 SCANNER OPERATION HOST SCANNER COMMANDS ³115916 Transmit Scanner ID byte with receipt of an “i” (69H) via RS232 - The ID byte is transmitted as

Página 37

35SCANNER OPERATION HOST SCANNER COMMANDS ³141715 Use Protocol Prefix and Suffix for Bar Code Transmission ³141705 * No Protocol Prefix and Suff

Página 38

36 PREFIXES/SUFFIXES Scan the Enter Configuration Mode bar code before trying to set these features (see the Multi-Code Method on page 2). USER

Página 39

37PREFIXES/SUFFIXES USER CONFIGURABLE ID CHARACTERS, CODE SPECIFIC ³105507 * Use Configurable Code ID Bytes as Prefixes - User configured, code s

Página 40

38 PREFIXES/SUFFIXES USER CONFIGURABLE ID CHARACTERS, CODE SPECIFIC ‡ Enter configuration mode then scan this bar code followed by the three cod

Página 41

39PREFIXES/SUFFIXES STANDARD PREFIX CHARACTERS ³116615 Enable STX Prefix - The scanner will transmit a Start of TeXt (ASCII 02H) before each bar

Página 42 - PREFIXES/SUFFIXES

40 PREFIXES/SUFFIXES STANDARD PREFIX CHARACTERS ³107916 Enable SANYO ID Characters ³107906 * Disable SANYO ID Characters ³105512 Enable Manufact

Página 43

41PREFIXES/SUFFIXES STANDARD SUFFIX CHARACTERS ³116613 * Enable CR Suffix - The scanner transmits a carriage return after each bar code. ³116603

Página 44

42 PREFIXES/SUFFIXES LONGITUDINAL REDUNDANCY CHECK A Longitudinal Redundancy Check (LRC) is an error checking character that is calculated across

Página 45

43PREFIXES/SUFFIXES CHARACTER REPLACEMENTS To replace a character: 1. Scan the enter/exit configuration mode bar code (on page 2). 2. Scan the ch

Página 46

ivTABLE OF CONTENTS Keyboard Enable Keyboard Emulation... 56 Country/Scan Co

Página 47

44 PREFIXES/SUFFIXES USER CONFIGURABLE SUFFIXES, ALL DATA Note: Scan the Enter/Exit Configuration mode code before trying to set this feature.

Página 48

45PREFIXES/SUFFIXES SPECIAL FORMATS ³107914 Enable SINEKO Mode ³107904 * Disable SINEKO Mode ³116711 Enable Newcode Formatting Mode A ³116701 *

Página 49

46 CODE FORMATTING UPC/EAN FORMATTING ³107517 * Transmit UPC-A Check Digit ³107507 Do Not Transmit UPC-A Check Digit ³107516 Transmit UPC-E Check

Página 50

47CODE FORMATTING UPC/EAN FORMATTING ³107513 Transmit Lead Zero on UPC-E - This option will transmit a zero before each UPC-E bar code. ³107503 *

Página 51

48 CODE FORMATTING CODABAR FORMATTING ³107717 Transmit Codabar Start/Stop Characters -Transmits Codabar’s Start/stop characters before and after

Página 52 - CODE FORMATTING

49CODE FORMATTING CODE 39 FORMATTING ³107715 Transmit Mod 43 Check Digit on Code 39 - This feature works in conjunction with Mod 43 Check Digit on

Página 53

50 CODE FORMATTING PLESSEY ³107816 Transmit UK Plessey Check Digit - The scanner will transmit UK Plessey Check Digit characters and must be use

Página 54

51RS232 ³415554 * Enable RS232 Mode - the scanner will work with RS232 +/-12V serial output. PARITY FEATURES A parity bit is an extra data bit

Página 55

52 RS232 BAUD RATE ³415830 2400 BAUD Rate ³415820 1200 BAUD Rate ³415810 600 BAUD Rate ³415800 300 BAUD Rate DATA/STOP BITS ³116013 8 Data Bi

Página 56

53RS232 HARDWARE HANDSHAKING ³124510 Invert RTS Polarity (RSV1)-12V = Active +12V = Inactive ³124500 * Standard RTS Polarity - Use standard RTS

Página 57 - BAUD RATE

vTABLE OF CONTENTS MS9535 VoyagerBT®... 83 MS9535-5M VoyagerBT®

Página 58 - ARDWARE HANDSHAKING

54 RS232 SOFTWARE HANDSHAKING ³115913 Enable ACK/NAK - After transmitting data, wait for an ACK (06H) or a NAK (15H) response from the host. If A

Página 59 - HARDWARE HANDSHAKING

55RS232 MISCELLANEOUS ³116110 Enable French PC Term - The scanner transmits PC type make/break scan codes instead of ASCII data characters. The

Página 60 - SOFTWARE HANDSHAKING

56 KEYBOARD ENABLE KEYBOARD EMULATION ³999994 Load Keyboard Wedge Defaults - Loads the default settings for keyboard wedge mode. ³5155153Enable S

Página 61 - MISCELLANEOUS

57KEYBOARD COUNTRY/SCAN CODE TABLE SELECTS ³416200 Belgium Keyboard ³4162100Japan Keyboard ³416270 IBM 4700 Financial Keyboard ³416290 Sweden/Finl

Página 62 - KEYBOARD

58 KEYBOARD ‘DUMB’ TERMINAL SELECTIONS Note: The following terminals may require custom cables. ³316400 IBM Terminal Keyboards ³316410 Reserved

Página 63

59KEYBOARD SPECIAL KEYBOARD FEATURES ³116311 Transmit Make Code Only - Not available on all models. ³116301 * Transmit Make/Break Code - Not ava

Página 64

60 KEYBOARD SPECIAL KEYBOARD FEATURES ³116214 Enable Caps Lock (XT) ³116204 * Disable Caps Lock (XT) ³116316 Send Numbers as Keypad Data - All d

Página 65

61KEYBOARD INTERSCAN CODE DELAYS ³816580 * InterScan Code Delay 800 msec - The time specified represents the amount of time between individual 1

Página 66

62 KEYBOARD Control Set #1 ASCII (HEX) ASCII Control Extended Key 00H Null Numeric Keypad + (Plus) 01H SOH Num Lock 02H STX Down Arrow 03H

Página 67

63OCIA ³415544 Enable OCIA Mode - Select this option if communications requires OCIA (Optically Coupled Interface Adapter). The host clocks this

Página 68

1INTRODUCTION Your new scanner has been factory configured with a set of default parameters. Since many host systems have unique formats and prot

Página 69

64 LIGHT PEN PARAMETERS ³415524 Enable Light Pen Mode - Select this option if the scanner will be used in place of a light pen. It provides light

Página 70 - LIGHT PEN PARAMETERS

65LIGHT PEN PARAMETERS SET NARROW ELEMENT WIDTH ³116912 10x Narrow Element Border - Allows the transmission of Light Pen/Wand emulation using a 1

Página 71

66 MS9520/9540-00 LASER EMULATION MODE ENABLE HANDHELD LASER EMULATION MODE The MS9520-00 and MS9540-00 leave the factory with Laser Emulation int

Página 72 - LASER EMULATION MODE

67IBM® 46XX CONFIGURATION IBM PORT ³415504 Enable IBM 46xx Communication - For IBM 46xx SIOC/RS485 communications. Not all scanners support this

Página 73 - 46XX CONFIGURATION

68 USB ³4155114Enable USB Interface♦ ³999978 Enable Low Speed USB Defaults♦ ♦ This feature is limited to Metrologic scanners without integrated

Página 74 - ³3164010

69USB ³117817 Enable Barcode ID ³117807 Disable Barcode ID ³119817 Enable USB Reserve Code #1 ³119807 Disable USB Reserve Code #1 ³999973 Enable US

Página 75

70 CODE BYTES USAGE The features that use these code bytes for configuration require that the scanner be in Configuration Mode. The Enter/Exit

Página 76 - CODE BYTES USAGE

71CODE BYTES USAGE RESERVED CODES ³999988 ~ Enable Reserved Code - Contact Metrologic for information about this feature. ³999987 ~ Disable Res

Página 77

72 CODE BYTES USAGE ASCII REFERENCE TABLE HEX Value Decimal Value/ Code Byte Value Character Control Keyboard Eqv 00 000 NUL @ 01 001 SOH A 02

Página 78

73CODE BYTES USAGE ASCII REFERENCE TABLE HEX Value Decimal Value/ Code Byte Value Character Control Keyboard Eqv 1D 029 GS ^ 1E 030 RS _ 1F

Página 79

2 BAR CODE CONFIGURATION METHODS Please note that the MS6220 Pulsar can only be configured using the Multi-Code Method. To properly configure

Página 80

74 CODE BYTES USAGE ASCII REFERENCE TABLE HEX Value Decimal Value/ Code Byte Value Character Control Keyboard Eqv 3C 060 < less than 3D 06

Página 81

75CODE BYTES USAGE ASCII REFERENCE TABLE HEX Value Decimal Value/ Code Byte Value Character Control Keyboard Eqv 5A 090 Z 5B 091 [ shift K 5

Página 82

76 CODE BYTES USAGE ASCII REFERENCE TABLE HEX Value Decimal Value/ Code Byte Value Character Control Keyboard Eqv 79 121 y 7A 122 z 7B 1

Página 83

77CODE BYTES USAGE EXTENDED KEY CODE REFERENCE TABLE Key At Scan Code PS2 Scan Code 3151 Prefix/Suffix Value Hex = Decimal F8 0AH 42H 3FH 9

Página 84 - & MS9540 VOYAGERCG

78 MS9520 VOYAGER® & MS9540 VOYAGERCG® SERIES ACTIVATION RANGE Use these bar codes to select infrared (IR) sensor activation range for sensing

Página 85

79MS9520 VOYAGER® & MS9540 VOYAGERCG® SERIES LASER/SCAN MODES ³418304 * Normal Scan - Laser turns on after the IR senses a bar code. The las

Página 86

80 MS9520 VOYAGER® & MS9540 VOYAGERCG® SERIES SAME SYMBOL TIME OUTS If using an MS5145 Eclipse, the MS9524 or MS9544 VoyagerPDF, please go to

Página 87 - SERIES

81MS9524 & MS9544 VOYAGERPDF® SERIES ³100010 * Enable PDF ³100000 Disable PDF ³115010 * Enable Audible Indicator ³115000 Disable Audible Indic

Página 88

82 MS9524 & MS9544 VOYAGERPDF® SERIES ³115007 * Enabe RSS 2D Linkage - Transmits the 1D RSS with out scanning the 2D portion. ³115017 Disable

Página 89 - MS9535 VOYAGERBT

83MS9535 VOYAGERBT® When the MS9535 acts as a client to other Bluetooth devices that have a Bluetooth address that is NOT headed with FNC3 but is j

Página 90

3CODE TYPES AND DECODE RULES Bar code descriptions marked with an asterisk ( * ) define a feature that is a factory default. Bar codes marked with

Página 91 - MS9535-5M VOYAGERBT

84 MS9535 VOYAGERBT® ³8195300 Sleep in 5 Minutes - The scanner will go into sleep mode after the laser has been off for 5 minutes. ³8195600 Sleep i

Página 92

85MS9535-5M VOYAGERBT® ³123910 Enable Inventory Mode – Bar code data that is scanned is stored in the scanner’s expanded memory base. The data wil

Página 93

86 MS9535-5M VOYAGERBT® ³998049 Clear Inventory Records - Will clear all stored bar code data in memory. ³125612 Enable Auto Clear Records – will a

Página 94 - IS4125 / IS4225 SCAN ENGINES

87MS9535-5M VOYAGERBT® INVENTORY QUANTITY BAR CODES** The following inventory quantity bar codes will enable the user to enter a quantity from 1 t

Página 95 - MISCELLANEOUS FEATURES

88 IS4125 / IS4225 SCAN ENGINES ³120315 Disable Old Serial Program ³120305 Enable Old Serial Program ³120311 Enable TTL UART ³120312 Enable Non Buf

Página 96

89MISCELLANEOUS FEATURES CUSTOM DEFAULTS Metrologic manufactures several scanners for OEM applications. These scanners may use a different set

Página 97

90 MISCELLANEOUS FEATURES SERIAL PROGRAM MODE For Serial Program Mode, all commands must be framed by an STX (02 Hex) and ETX (03 Hex). To recal

Comentários a estes Manuais